Abstract

Optimal health services require supporting examinations in diagnosing a disease. On lumbosacral examination, radiograph quality is often less than optimal. Digital radiography is a new system on x-ray machines that has features for better image processing, one of which is flexible noise control (FNC). This study aims to determine the effect of digital radiography processing settings on image quality on lateral position lumbosacral examination. In this study using a qualitative descriptive method with an experimental or experimental research approach. The results showed that there was an effect of digital radiography processing settings on image quality with the FNC feature. This was shown by using the Image J application, there was a change in the standard deviation value before and after processing with the FNC feature. It is known that the FNC feature suppresses the noise value in the radiograph images.

 

 

References

Bushong, C. Stewart. (2017). Radiologic Science for Technologists.

Krystal M. Kirby, Timothy. R. L., & Bartholmai. J. B. (2022). Impact Of Flexible Noise Control (FNC) Image Processing Parameters On Portable Chest Radiography, https//:doi. org/10. 1002/acm2. 13812

Kurnianto, K., Putra, I. M., & Susila, I. P. (2013). Perekayasaan perangkat radiografi digital untuk industri. Prosiding Pertemuan Ilmiah Perekayasaan Perangkat Nuklir, November, 261–274.

Labania, H. M., P. Rindayani, Kasman, Abd. Rahman, & S. Ulum. (2021). Analisis Kontras Digital Radiography Dengan Menggunakan ImageJ. Gravitasi, 20(1), 10–18. https://doi.org/10.22487/gravitasi.v20i1.15521

Lampignano, J. P., & Kendrick, L. E. (2018). Textbook Of Radiographic Positioning and Related Anatomy. In Elsevier (Vol. 9, Issue 1).

Long, B. W., Rollins, J. H., & Smith, B. J. (2016). Merrill ’ S Atlas of, Radiographic Positioning dan Procedures (Thirteenth). Elsevier Inc.

Mean Dan Median Terhadap Reduksi Noise. Jurnal Media Informata, 12(1), 21-30

Schneider, C. A., Rasband, W. S., & Eliceiri, K. W.(2012). NIH Image to ImageJ: 25 years of image analysis. Nature methods, 9(7), 671-675. https://doi.org/10. 1038/nmeth.2089

Seeram, E. (2019). Digital Radiography: Physical Principles and Quality Control, Second Edition. In Digital Radiography: Physical Principles and Quality Control, Second Edition. https://doi.org/10.1007/978-981-13-3244-9

Slonim, L. (2016). Clark’s positioning in radiography. 11th edn. In Medical Journal of Australia (13th ed., Vol. 146, Issue S1). https://doi.org/10.5694/j.1326-5377.1987.tb104401.x

Sparzinanda, E., Nehru, N., & Nurhidayah, N. (2018). Pengaruh Faktor Eksposi Terhadap Kualitas Citra Radiografi. Journal Online of Physics, 3(1), 14–22. https://doi.org/10.22437/jop.v3i1.4428

Utami, P. A., Saputro, D. A., & Felayani, F. (2018). RADIOLOGI DASAR I Aplikasi Dalam Teknik Radiografi,Anatomi Radiologi dan Patofisiologi(Ekstremitas Atas, Ekstremitas Bawah dan Vertebra) (3rd ed.). Inti Medika Pustaka.

Wedianto, A., Sari, H. L., & H, Y. S. (2016). Analisa Perbandingan Metode Filter Gaussian,

Wita, A., & Fransiska, E. (2018). Hubungan Kv Terhadap Ketebalan Objek Ayu Wita Sari 2018. Journal of Health, 17–21.

Zelviani, S. (2017). Kualitas Citra pada Direct Digital Radiography dan Ccomputed Radiography. Jurnal Teknosains, 49–62.

Downloads

Published

2022-11-30

How to Cite

Rini Hatma Rusli, & Bambang Ariyanto. (2022). Pengaruh Pengaturan Processing Digital Radiography terhadap Kualitas Gambar pada Pemeriksaan Lumbosacral Posisi Lateral di Rumah Sakit Bhayangkara Makassar. Jurnal Ilmu Kedokteran Dan Kesehatan Indonesia, 2(3), 235–240. https://doi.org/10.55606/jikki.v2i3.4170