Pengaruh Variasi Nilai mA (Mili Ampere) dan s (Second) yang Berbeda Dengan Nilai mAs yang Sama Terhadap Paparan Medik yang Diterima Pasien

Authors

  • Maritje S. J. Malisngorar Politeknik Muhammadiyah Makassar
  • Ira Sandi Tunny Politeknik Muhammadiyah Makassar
  • Amelia Niwele Politeknik Muhammadiyah Makassar
  • Akhmadi Rini Hatma Rusli Politeknik Muhammadiyah Makassar
  • Iksan Soumena Politeknik Muhammadiyah Makassar
  • Bambang Ariyanto Politeknik Muhammadiyah Makassar

DOI:

https://doi.org/10.55606/jikki.v2i2.4172

Keywords:

Mili ampere, Second, Medical exposure

Abstract

This study aims to find out how to measure exposure dose medical techniques which accepted the patients with a variety of ma and s at the same mas value and the effect of variations in the value of mili ampere and second different with the same mas value to medical exposure dose received by patients. This type of study is an observational descriptive with the approach of the experimental or trial. using gauges medic exposure dose, x-ray multimeter with research indicator mili ampere and second are different but the same mas. From these results it can be concluded the highest medical exposure dose received by patients is the variation of 200 ma and 0.05 s with a dose value of 5.533 mgy / s. this is due to the amount of flow tube (ma). it can be concluded that the greater ma is used, the greater the dose the patient received medical.

References

Akhadi, M. 2000. Dasar-dasar Proteksi Radiasi, PT Rineka Cipta, Jakarta.

Badan Pengawas Tenaga Nuklir (BAPETEN). 2021. "Pedoman Teknis Penerapan Tingkat Panduan Diagnostik Indonesia." BAPETEN,

Ballinger, P. W dan Frank, E. D. 2003. Merril’s Atlas of Radiographic Position and Radiologic Procedures, Volume One, Tenth Edition. USA:Mosby

Bushong, S. Carlyle. 2001 Radiologic Scicence for Technologist, Seventh Edition. Toronto :Mosby Company

Darmini, J. Dahjono, dan Asri Indah Aryani. 2021."Penerimaan Dosis Radiasi Pada Pemeriksaan Radiografi di Indonesia.",

Meredith, W. J. dan Massey, J. B. 1997. Fundamental Physics of Radiology, Bristol:John Wright and So ns Ltds

Yunita Sari Purba dan Indah Permata Sari. 2020. "Pengukuran Paparan Dosis Sinar X Sebelum dan Sesudah Pengendalian Pada Proses Pekerjaan Radiologi." Repository Binawan,

Downloads

Published

2022-07-30

How to Cite

Maritje S. J. Malisngorar, Ira Sandi Tunny, Amelia Niwele, Akhmadi Rini Hatma Rusli, Iksan Soumena, & Bambang Ariyanto. (2022). Pengaruh Variasi Nilai mA (Mili Ampere) dan s (Second) yang Berbeda Dengan Nilai mAs yang Sama Terhadap Paparan Medik yang Diterima Pasien. Jurnal Ilmu Kedokteran Dan Kesehatan Indonesia, 2(2), 227–231. https://doi.org/10.55606/jikki.v2i2.4172

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)