Prosedur Pemeriksaan CT Scan Kepala Polos pada Kasus Microcephaly di Instalasi Radiologi RS Roemani Muhammadiyah Semarang

(Studi Kasus pada Pasien Pediatrik Usia 5 Bulan)

Authors

  • Shintanaya Anggraeni Universitas ‘Aisyiyah Yogyakarta
  • Sofie Nornalita Dewi Universitas ‘Aisyiyah Yogyakarta
  • Ike Ade Nur Liscyaningsih Universitas ‘Aisyiyah Yogyakarta

DOI:

https://doi.org/10.55606/jikki.v5i2.6074

Keywords:

CT Scan, Dose Reduction, Microcephaly, Radiation Protection, Radiology Diagnostics, Spiral CT Technique

Abstract

Microcephaly is a condition in which a child's head circumference is smaller than the average for age and gender. The diagnosis can be made using a CT Scan, which should be adjusted to the patient's age according to the IAEA protocol (2012), with an ideal effective dose of 1.8–3.8 mSv for a tube current of 200 mAs. However, at the Radiology Installation of Roemani Muhammadiyah Hospital Semarang, the examination was carried out without differentiating age, resulting in an excess dose of 9.317 mSv. This study aims to evaluate the procedures, diagnostic information, and radiation protection in plain head CT Scans of pediatric patients with microcephaly. This study used a qualitative approach through observation, interviews, and documentation of 3 radiographers, 1 PPR, and 1 radiologist. The results showed no protection for patients and only basic protection for companions. CT Scans showed decreased brain volume and ventriculomegaly. It is recommended that the CT Scan protocol be adjusted to the child's age to reduce the radiation dose, through the setting of exposure factors, slice thickness, and pitch.

References

Adlini, M. N. (2022). Buku Penuntun Praktikum Anatomi Dan Fisiologi Manusia. Buku Penuntun Praktikum Anatomi Dan Fisiologi Manusia, 48.

Alatas, Z. (2017). Risiko Radiasi Dari Computed Tomography Pada Anak. Jurnal Forum Nuklir, 8(2), 181. https://doi.org/10.17146/jfn.2014.8.2.3712

Bruno, L. (2019). Anatomi & Fisiologi untuk mahasiwa kesehatan. In Journal of Chemical Information and Modeling (Vol. 53, Issue 9).

Hanzlik, E., & Gigante, J. (2017). Microcephaly. Children, 4(6). https://doi.org/10.3390/children4060047

Inoue, Y., Itoh, H., Waga, A., Sasa, R., & Mitsui, K. (2022). Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables. Tomography, 8(2), 985–998. https://doi.org/10.3390/tomography8020079

International Atomic Energy Agency (IAEA). (2012). Radiation protection in Paediatric Radiology, Safety reports series no. 71, IAEA, Vienna . In IAEA Safety Reports Series (Vol. 71). https://www-pub.iaea.org/MTCD/Publications/PDF/Pub1543_web.pdf

Jung, H. (2021). Basic Physical Principles and Clinical Applications of Computed Tomography. Progress in Medical Physics, 32(1), 1–17. https://doi.org/10.14316/pmp.2021.32.1.1

Lampignano. (2018). Bontrager’s TEXTBOOK of RADIOGRAPHIC POSITIONING and RELATED ANATOMY NINTH EDITION.

Long. (2016). Merrill’s Atlas of Radiographic Volume 3.

Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia Nomor 4 Tahun 2020 Tentang Keselamatan Radiasi Pada Penggunaan Pesawat Sinar-X Dalam Radiologi Diagnostik Dan Intervensional, Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia 1 (2020). https://jdih.bapeten.go.id/unggah/dokumen/peraturan/1028-full.pdf

Petribu, N. C. de L., Fernandes, A. C. V., Abath, M. de B., Araújo, L. C., de Queiroz, F. R. S., Araújo, J. de M., de Carvalho, G. B., & van der Linden, V. (2018). Common findings on head computed tomography in neonates with confirmed congenital Zika syndrome. Radiologia Brasileira, 51(6), 366–371. https://doi.org/10.1590/0100-3984.2017.0119

Romans, L. E. (2011). Computed Tomography for Technologist : a comprehensive text. Wolters Kluwer Health.

Sari, R. T. D., Adi, K., & Anam, C. (2014). Pengukuran dan Penghitungan Volume Phantom dari Citra Computed Tomography (Ct) Scan. Youngster Physics Journal, 3(4), 221–226.

Seeram, E. (2022). Computed Tomography - E-Book: Computed Tomography - E-Book. Saunders. https://books.google.co.id/books?id=faZ1EAAAQBAJ

Vaughn, J. A., & Poussaint, T. Y. (2023). Pediatric Head CT. In Problem Solving in Pediatric Imaging. Elsevier. https://doi.org/10.1016/B978-1-4377-2612-1.00025-9

Yunus, B., Bandu, K., Radiologi, B., Program, M., Kedokteran, S., Kedokteran, F., & Unuversitas, G. (2019). Efek radiasi sinar-x pada anak-anak. Makassar Dental Journal, 8(2), 97–104. https://doi.org/10.35856/mdj.v8i2.278

Downloads

Published

2025-05-26

How to Cite

Shintanaya Anggraeni, Sofie Nornalita Dewi, & Ike Ade Nur Liscyaningsih. (2025). Prosedur Pemeriksaan CT Scan Kepala Polos pada Kasus Microcephaly di Instalasi Radiologi RS Roemani Muhammadiyah Semarang : (Studi Kasus pada Pasien Pediatrik Usia 5 Bulan). Jurnal Ilmu Kedokteran Dan Kesehatan Indonesia, 5(2), 97–111. https://doi.org/10.55606/jikki.v5i2.6074

Similar Articles

<< < 1 2 3 4 5 6 7 > >> 

You may also start an advanced similarity search for this article.